Part identity
BVM 504
Powersupply
Alenia Marconi Systems Ltd
Avg quote: 14 minFulfilled from Anaheim, CAAS9120:2025 · ISO 9001 · FAA AC 00-56BC of C, lot & date code with every line
Part description
Powersupply
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
AM
Manufacturer
Alenia Marconi Systems Ltd
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →NSN Information for Part Number BVM 504 with NSN 6130-01-453-0467, 6130014530467
Characteristics Data of NSN 6130-01-453-0467, 6130014530467
| MRC | Criteria | Characteristic |
|---|---|---|
| CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT 2 2ND POWER OUTPUT 2 3RD POWER OUTPUT 2 4TH POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR, PLUG AND CONNECTOR WITH LEADS 1ST POWER OUTPUT CONNECTOR, PLUG AND CONNECTOR WITH LEADS 2ND POWER OUTPUT CONNECTOR, PLUG AND CONNECTOR WITH LEADS 3RD POWER OUTPUT SCREW AND BUS (BAR) CONDUCTOR 4TH POWER OUTPUT |
| CWHM | INPUT CURRENT RATING | 10.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT |
| CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT 4.0 DC AMPERES NOMINAL 2ND POWER OUTPUT 8.0 DC AMPERES MINIMUM AND 12.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT 75.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
| ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 90.0 AC VOLTS MINIMUM AND 264.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
| CWWY | POWER SUPPLY EFFICIENCY LINE | 75.0 |
| ABMK | OVERALL WIDTH | 5.000 INCHES MAXIMUM |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| ABHP | OVERALL LENGTH | 9.650 INCHES MAXIMUM |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| APPA | OUTPUT VOLTAGE RATING | 24.0 DC VOLTS NOMINAL 1ST POWER OUTPUT -12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT 12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT 5.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
| AGAV | III END ITEM IDENTIFICATION | NIMROD TRAINER SIMULATOR |