Part identity
CB-20A
Circuit Breaker
Customair Automotive Air Conditioning Pty Ltd
Avg quote: 14 minFulfilled from Anaheim, CAAS9120:2025 · ISO 9001 · FAA AC 00-56BC of C, lot & date code with every line
Part description
Circuit Breaker
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
CA
Manufacturer
Customair Automotive Air Conditioning Pty Ltd
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →NSN Information for Part Number CB-20A with NSN 5925-01-600-7960, 5925016007960
Characteristics Data of NSN 5925-01-600-7960, 5925016007960
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ABMK | OVERALL WIDTH | 0.790 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.240 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.790 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.640 INCHES NOMINAL |
| ADTV | CASE MATERIAL | METAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.690 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.560 INCHES NOMINAL |
| AJEC | BOSS HEIGHT | 0.560 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.250 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES DC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 14.0 DC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1.5 DC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRQ | RESET METHOD | AUTOMATIC |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
| CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM ALL LOCATIONS AND 185.0 DEG FAHRENHEIT MAXIMUM ALL LOCATIONS |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SERIES 12X SHORTSTOP CIRCUIT BREAKER,20AMP DC |
| THSD | THREAD SERIES DESIGNATOR | UNF |