Part identity
CB-30A
Circuit Breaker
Customair Automotive Air Conditioning Pty Ltd
Avg quote: 14 minFulfilled from Anaheim, CAAS9120:2025 · ISO 9001 · FAA AC 00-56BC of C, lot & date code with every line
Part description
Circuit Breaker
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
CA
Manufacturer
Customair Automotive Air Conditioning Pty Ltd
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →NSN Information for Part Number CB-30A with NSN 5925-01-600-8047, 5925016008047
Characteristics Data of NSN 5925-01-600-8047, 5925016008047
| MRC | Criteria | Characteristic |
|---|---|---|
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.560 INCHES NOMINAL |
| AAQL | Body Style | SINGLE POLE TYPE |
| ADAU | Body Height | 0.640 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
| AKPX | Pole Quantity | 1 |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 14.0 DC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1.5 DC ALL LOCATIONS |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| AJEC | Boss Height | 0.560 INCHES NOMINAL |
| ADAT | Body Width | 0.790 INCHES NOMINAL |
| CXCY | Part Name Assigned By Controlling Agency | SERIES 12X SHORTSTOP CIRCUIT BREAKER,30AMP DC |
| CRCF | Trip Release Ambient Temp Rating | -40.0 DEG FAHRENHEIT MINIMUM ALL LOCATIONS AND 185.0 DEG FAHRENHEIT MAXIMUM ALL LOCATIONS |
| CPRQ | Reset Method | AUTOMATIC |
| AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED HOLE |
| ADTV | Case Material | METAL |
| CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| ABMK | Overall Width | 0.790 INCHES NOMINAL |
| CQJX | Nominal Thread Size | 0.190 INCHES |
| ADAQ | Body Length | 1.240 INCHES NOMINAL |
| AJWX | Mounting Surface To Terminal End Distance | 1.250 INCHES NOMINAL |
| CQQC | Trip Release Duty Cycle | CONTINUOUS ALL LOCATIONS |
| CMLP | Thread Quantity Per Inch | 32 |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.690 INCHES NOMINAL |
| CPRJ | Trip Release Method | THERMAL ALL LOCATIONS |
| AEBV | Unthreaded Mounting Hole Diameter | 0.196 INCHES NOMINAL |
| THSD | Thread Series Designator | UNF |
