Part identity
0D2700
END Item Identification: Instrument landing system AN/GRN-29(V) Special Features: Weapon system essential General Characteristics Item Description: Floor type;movable;shall be capable of condensing A min of 15 pints of water daily at 80 deg f;with 60 percent relative humidity/ansi sid B149.1/;24 in. max H, 270 sq in. max occupied floor space;compressor motor, 115 volts, A.C., 60 cycle, single phase;built-in humidistat and off-continuous run control switch;automatic overflow control and indicator light;moisture container shall have A min capacity equal to the condensing capabilities of the unit
Frigidaire Co
Part description
END Item Identification: Instrument landing system AN/GRN-29(V) Special Features: Weapon system essential General Characteristics Item Description: Floor type;movable;shall be capable of condensing A min of 15 pints of water daily at 80 deg f;with 60 percent relative humidity/ansi sid B149.1/;24 in. max H, 270 sq in. max occupied floor space;compressor motor, 115 volts, A.C., 60 cycle, single phase;built-in humidistat and off-continuous run control switch;automatic overflow control and indicator light;moisture container shall have A min capacity equal to the condensing capabilities of the unit
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
Manufacturer
Frigidaire Co
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →Characteristics Data of NSN 4440-00-566-0616, 4440005660616
| MRC | Criteria | Characteristic |
|---|---|---|
| TEXT | General Characteristics Item Description | FLOOR TYPE;MOVABLE;SHALL BE CAPABLE OF CONDENSING A MIN OF 15 PINTS OF WATER DAILY AT 80 DEG F;WITH 60 PERCENT RELATIVE HUMIDITY/ANSI SID B149.1/;24 IN. MAX H,270 SQ IN. MAX OCCUPIED FLOOR SPACE;COMPRESSOR MOTOR,115 VOLTS,A.C.,60 CYCLE,SINGLE PHASE;BUILT-IN HUMIDISTAT AND OFF-CONTINUOUS RUN CONTROL SWITCH;AUTOMATIC OVERFLOW CONTROL AND INDICATOR LIGHT;MOISTURE CONTAINER SHALL HAVE A MIN CAPACITY EQUAL TO THE CONDENSING CAPABILITIES OF THE UNIT |
| CRTL | Criticality Code Justification | FEAT |
| AGAV | End Item Identification | INSTRUMENT LANDING SYSTEM AN/GRN-29(V) |
| MRC | Decoded Requirement | Clear Text Reply |
| FEAT | Special Features | WEAPON SYSTEM ESSENTIAL |
