Part identity
3TC14-35
Circuit Breaker
Omnitech Eichut Ltd
Avg quote: 14 minFulfilled from Anaheim, CAAS9120:2025 · ISO 9001 · FAA AC 00-56BC of C, lot & date code with every line
Part description
Circuit Breaker
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
OE
Manufacturer
Omnitech Eichut Ltd
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →Characteristics Data of NSN 5925-01-173-1763, 5925011731763
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJE | THREAD PITCH DIAMETERS | 0 444 TO 0 447 INCHES |
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ABXD | BUSHING LENGTH | 0 250 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1 100 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0 781 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0 704 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1 218 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35 0 AMPERES AC AND 35 0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120 0 AC AND 28 0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000 0 AC AND 6000 0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138 0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0 469 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4 000 MINIMUM AT 200 PCT AND 20 000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND DUSTTIGHT AND CORROSION RESISTANT AND HUMIDITY RESISTANT AND EXPLOSION PROOF |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | -55 0 DEG CELSIUS MINIMUM AND 121 0 DEG CELSIUS MAXIMUM SINGLE LOCATION |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 400 0 SINGLE LOCATION |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB WSCREW |