Part identity
16-001-07
Resistor Variable W
Racal Comsec Ltd
Avg quote: 14 minFulfilled from Anaheim, CAAS9120:2025 · ISO 9001 · FAA AC 00-56BC of C, lot & date code with every line
Part description
Resistor Variable W
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
RC
Manufacturer
Racal Comsec Ltd
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →NSN Information for Part Number 16-001-07 with NSN 5905-00-583-7950, 5905005837950
Characteristics Data of NSN 5905-00-583-7950, 5905005837950
| MRC | Criteria | Characteristic |
|---|---|---|
| AAPN | SECTION QUANTITY | 1 |
| AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 0.300 INCHES NOMINAL |
| ABTB | MOUNTING HOLE DIAMETER | 0.086 INCHES NOMINAL |
| ABWV | SHAFT DIAMETER | 0.125 INCHES NOMINAL |
| ABXF | SHAFT LENGTH | 0.062 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.250 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.250 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.312 INCHES NOMINAL |
| AEDX | SHAFT STYLE | ROUND, SLOTTED |
| AEFD | ACTUATOR TYPE | SINGLE SHAFT |
| AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
| AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 1.000 INCHES NOMINAL |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
| AXGY | MOUNTING METHOD | TERMINAL |
| CQCC | ELECTRICAL RESISTANCE PER SECTION | 1.000 KILOHMS SINGLE SECTION |
| CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
| CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 120.0 SINGLE SECTION |
| CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
| CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
| CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
| TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |