Part identity
010-1409
Switch Thermostatic
Ranco Inc Ranco Controls Div
Avg quote: 14 minFulfilled from Anaheim, CAAS9120:2025 · ISO 9001 · FAA AC 00-56BC of C, lot & date code with every line
Part description
Switch Thermostatic
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
RI
Manufacturer
Ranco Inc Ranco Controls Div
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →NSN Information for Part Number 010-1409 with NSN 5930-00-253-9327, 5930002539327
Characteristics Data of NSN 5930-00-253-9327, 5930002539327
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | III OVERALL LENGTH | 3.344 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 1.797 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 3.062 INCHES NOMINAL |
| AEVT | CAPILLARY TUBE LENGTH | 76.000 INCHES NOMINAL |
| AEVU | BULB LENGTH | 1.500 INCHES NOMINAL |
| AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | YSUPPLY CLASS AOE, NIMITZ CLASS CVN, ARLEIGH BURKE CLASS DDG, LANDING CRAFT, UTILITY, 115 FT, OLIVER PERRY CLASS FFG, AUSTIN SHIP CLASS LPD-4 AMPHIBIOUS TRANSPORT DOCKS, TARAWA CLASS LHA, TICONDEROGA CLASS CG (47), FORRESTAL CLASS CV |
| AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| AXGY | MOUNTING METHOD | BASE |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CSCF | TERMINAL TYPE | TAB W/SCREW |
| CTHF | CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 2.3 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 4.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 6.5 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CTYM | CONTACT ADJUSTMENT RANGE | -10.00/+55.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |