Part identity
1026964-000
Circuitbreaker
Serviceworks Australia Pty Ltd
Avg quote: 14 minFulfilled from Anaheim, CAAS9120:2025 · ISO 9001 · FAA AC 00-56BC of C, lot & date code with every line
Part description
Circuitbreaker
ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
SA
Manufacturer
Serviceworks Australia Pty Ltd
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →NSN Information for Part Number 1026964-000 with NSN 5925-01-149-7212, 5925011497212
Characteristics Data of NSN 5925-01-149-7212, 5925011497212
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ABHP | OVERALL LENGTH | 50.8 MILLIMETERS NOMINAL |
| ADAT | BODY WIDTH | 19.81 MILLIMETERS NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 17.14 MILLIMETERS MINIMUM AND 17.27 MILLIMETERS MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 39.62 MILLIMETERS NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 34.97 MILLIMETERS NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 12.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |