Part No. : 412Y-0191 | Alternate P/N : 412Y0191 | Manufacturer : teledyne reynolds inc |
Item Name: relay electromagnetic | NSN: 5945-01-338-3495 (5945013383495) | CAGE Code: 11532 |
FSC: 5945 Relays and Solenoids |
If you require part number 412Y-0191 from Teledyne Reynolds Inc which is described as a Relay Electromagnetic component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 412Y-0191 which is listed under the Federal Supply Class 5945 Relays and Solenoids. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5945013383495 and was produced under the CAGE Code 11532. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 412Y-0191 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 412Y-0191
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-338-3495 Item Description: Relay Electromagnetic | 5945 | 013383495 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
412y-0191 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.275 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.370 INCHES NOMINAL |
ADTV | CASE MATERIAL | BRASS |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AGAV | END ITEM IDENTIFICATION | 6625-01-224-4440 NETWORK ANALYZE |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 9 TERMINAL SINGLE MOUNTING FACILITY |
CBME | III CUBIC MEASURE | 0.009 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 28480-0490-1404 MANUFACTURERS SPECIFICATION CONTROL |
APNA | WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES DC RESISTIVE LOAD |