ASAP supports this specific part for replacement, spare-pool replenishment, retrofit, and urgent maintenance requirements. Quote requests can include alternate MPN, condition preferences, certification needs, and plant-specific receiving instructions so procurement gets a clear sourcing response before purchase.
Specifications
Certifications & documentation
- UL Recognized
- CE
- C of C available on request
WC
Manufacturer
Westwood Corporation
Authorized-distributor or qualified-aftermarket source. Parts shipped from this manufacturer include full traceability paperwork and counterfeit-mitigation per SAE AS6081.
View manufacturer profile →NSN Information for Part Number 04-26-0001 with NSN 5925-00-345-7746, 5925003457746
Characteristics Data of NSN 5925-00-345-7746, 5925003457746
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ADAQ | BODY LENGTH | 11.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 9.000 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 4.562 INCHES NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 9.875 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 3.000 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 9.875 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 3.000 INCHES NOMINAL |
| AJEC | BOSS HEIGHT | 0.312 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| CMLP | THREAD QUANTITY PER INCH | 20 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 250.0 AMPERES AC ALL LOCATIONS AND 250.0 AMPERES DC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 20000.0 AC ALL LOCATIONS AND 15000.0 DC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | UNC |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |