Part No. : D12-03 | Alternate P/N : D1203 | Manufacturer : acopian technical company |
Item Name: powersupply | NSN: 6130-00-202-2509 (6130002022509) | CAGE Code: 14749 |
FSC: 6130 Converters Electrical Non Rotating |
If you require part number D12-03 from Acopian Technical Company which is described as a Powersupply component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number D12-03 which is listed under the Federal Supply Class 6130 Converters Electrical Non Rotating. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6130002022509 and was produced under the CAGE Code 14749. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part D12-03 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-00-202-2509 Item PartTypeName: POWER SUPPLY | 6130 | 002022509 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
D12-03 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.265 INCHES MINIMUM AND 2.335 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.185 INCHES MINIMUM AND 1.315 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.775 INCHES MINIMUM AND 1.825 INCHES MAXIMUM |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -20.0 TO 71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 2ND POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 25.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 25.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | BOTTOM PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | BOTTOM PANEL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | PIN PLUG 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | PIN PLUG 2ND POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | AMBIENT AIR |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload