| Part No. : AT8060102011965 | Manufacturer : ametek programmable power inc | Item Name: powersupply |
| NSN: 6130-01-315-7518 (6130013157518) | CAGE Code: 25965 |
If you require part number AT8060102011965 from Ametek Programmable Power Inc which is described as a Powersupply component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number AT8060102011965 which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6130013157518 and was produced under the CAGE Code 25965. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part AT8060102011965 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6130-01-315-7518 Item PartTypeName: POWER SUPPLY | 6130 | 013157518 | N | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | 0 | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| AT8000 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 21.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | DETECT COOL TEST SET |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | 2000.0 FEET |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 103.5 AC VOLTS MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 126.5 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 207.0 AC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 253.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| AYNH | OPERATING AMBIENT TEMP RANGE | -0.1 TO 50.0 DEG CELSIUS |
| CBBL | FEATURES PROVIDED | CIRCUIT BREAKER AND OVER CURRENT PROTECTOR AND OVER VOLTAGE PROTECTOR AND INPUT VOLTAGE RANGE SWITCH |
| CWHQ | INPUT CONNECTION TYPE | CONNECTOR,RECEPTACLE SINGLE OPERATING POWER RQMT |
| CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
| CWKG | VENTILATION DESIGN TYPE | INTERNAL BLOWER |
| CWWJ | PROGRAM COMPATIBILITY | IEEE 488-1978 |
| CWWY | POWER SUPPLY EFFICIENCY LINE | 50.0 |
| FEAT | SPECIAL FEATURES | REFERENCE NUMBER BREAKDOWN AT8 PRODUCT FAMILY 06 NUMBER OF OUTPUT CHANNELS 0 SYSTEM OPERATING SOFTWARE ABLE 1 FRONT PANEL/PROGRAMMER CONFIG IS BLANK PANEL WITH PROGRAMMER AND BITOPTION 02 SYSTEM CONFIGURATION MASTERWITH ONE SLAVE 01 O |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload