Part No. : BA2-B0-26-620-3A1-C | Alternate P/N : BA2B0266203A1C | Manufacturer : carling technologies inc |
Item Name: circuitbreaker | NSN: 5925-01-384-9594 (5925013849594) | CAGE Code: 73559 |
FSC: 5925 Circuit Breakers |
If you require part number BA2-B0-26-620-3A1-C from Carling Technologies Inc which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number BA2-B0-26-620-3A1-C which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925013849594 and was produced under the CAGE Code 73559. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part BA2-B0-26-620-3A1-C today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. BA2-B0-26-620-3A1-C
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-384-9594 Item Description: Circuitbreaker | 5925 | 013849594 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ba2-B0-26-620-3a1-C | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.660 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
AJEC | Boss Height | 0.240 INCHES NOMINAL |
AKPX | Pole Quantity | 2 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
THSD | Thread Series Designator | UNC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
TTQY | Terminal Type And Quantity | 4 TAB W/SCREW |
AJWX | Mounting Surface To Terminal End Distance | 2.122 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.560 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |