Part No. : NEF423030-50DEGC | Alternate P/N : NEF42303050DEGC | Manufacturer : challenger electrical equipment corp |
Item Name: circuit breaker | NSN: 5925-00-062-6922 (5925000626922) | CAGE Code: 21810 |
FSC: 5925 Circuit Breakers |
If you require part number NEF423030-50DEGC from Challenger Electrical Equipment Corp which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number NEF423030-50DEGC which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925000626922 and was produced under the CAGE Code 21810. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part NEF423030-50DEGC today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. NEF423030-50DEGC
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-062-6922 Item Description: Circuit Breaker | 5925 | 000626922 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Nef423030-50degc | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 5.125 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
AKPX | Pole Quantity | 2 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 480.0 AC AND |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 15000.0 AC AND |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 DC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.378 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
AJEC | Boss Height | 0.188 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADAT | Body Width | 2.750 INCHES NOMINAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 6.062 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 4 COMPRESSION |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 5.219 INCHES NOMINAL |
ADAU | Body Height | 3.406 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC AND |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.375 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 DC ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.225 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |