Part No. : DGM M-10200VA-50HZ-40071034462 | Alternate P/N : DGMM10200VA50HZ40071034462 | Manufacturer : cooper crouse hinds llc |
Item Name: transformer power | NSN: 5950-01-380-0936 (5950013800936) | CAGE Code: D1739 |
FSC: 5950 Coils and Transformers |
If you require part number DGM M-10200VA-50HZ-40071034462 from Cooper Crouse Hinds Llc which is described as a Transformer Power component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number DGM M-10200VA-50HZ-40071034462 which is listed under the Federal Supply Class 5950 Coils and Transformers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5950013800936 and was produced under the CAGE Code D1739. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part DGM M-10200VA-50HZ-40071034462 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. DGM M-10200VA-50HZ-40071034462
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-380-0936 Item Description: Transformer Power | 5950 | 013800936 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Dgm M-10200va-50hz-40071034462 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 57.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 2ND CENTER GROUP |
AKPV | Mounting Facility Quantity | 6 2ND GROUP |
FEAT | Special Features | IN MRC CBBL RESISTORS ARE VARIBLE |
CWJS | Winding Operating Voltage | 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | Winding Operating Voltage | 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AKPV | Mounting Facility Quantity | 4 1ST GROUP |
ABKW | Overall Height | 267.0 MILLIMETERS NOMINAL |
AXGY | Mounting Method | UNTHREADED HOLE 1ST GROUP |
TTQY | Terminal Type And Quantity | 2 TERMINAL BLOCK W/SCREWS |
CRBZ | Winding Operating Current | 82.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ABHP | Overall Length | 410.0 MILLIMETERS NOMINAL |
ACZD | Transformer Winding Connection Type | DELTA-WYE |
AXGY | Mounting Method | SLOT 2ND GROUP |
AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
CRMJ | Winding Power Rating | 10.2 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CBBL | Features Provided | W/RESISTOR |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 165.0 MILLIMETERS MAXIMUM ALL MOUNTING FACILITIES 1ST CENTER GROUP |
BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
MRC | Decoded Requirement | Clear Text Reply |
ABTB | Mounting Hole Diameter | 16.0 MILLIMETERS NOMINAL 1ST GROUP |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
AARG | Reliability Indicator | NOT ESTABLISHED |
ACZC | Input-Output Phase Relationship | THREE PHASE TO SIX PHASE SINGLE COMPONENT |
ACZX | Winding Shielding Method | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ABMK | Overall Width | 173.0 MILLIMETERS NOMINAL |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 130.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 2ND CENTER GROUP |
AKNA | Inclosure Type | FULLY INCLOSED |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 260.0 MILLIMETERS NOMINAL ALL MOUNTING FACILITIES 1ST CENTER GROUP |
ABTD | Mounting Slot Width | 11.0 MILLIMETERS NOMINAL 2ND GROUP |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.