Part No. : JA1-A2-3-3 | Alternate P/N : JA1A233 | Manufacturer : eaton corp |
Item Name: circuit breaker | NSN: 5925-01-070-4829 (5925010704829) | CAGE Code: 74193 |
FSC: 5925 Circuit Breakers |
If you require part number JA1-A2-3-3 from Eaton Corp which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number JA1-A2-3-3 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925010704829 and was produced under the CAGE Code 74193. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part JA1-A2-3-3 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. JA1-A2-3-3
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-070-4829 Item Description: Circuit Breaker | 5925 | 010704829 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ja1-A2-3-3 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM |
AKPX | Pole Quantity | 1 |
AAQL | Body Style | SINGLE POLE TYPE |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC SINGLE LOCATION |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
MRC | Decoded Requirement | Clear Text Reply |
AFJN | Fragility Factor | MODERATELY RUGGED |
AJWX | Mounting Surface To Terminal End Distance | 1.875 INCHES MINIMUM AND 1.885 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
TTQY | Terminal Type And Quantity | 2 QUICK DISCONNECT, MALE |
AJEC | Boss Height | 0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM |
ADAT | Body Width | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT POLE ONE |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
ADTV | Case Material | PLASTIC |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
THSD | Thread Series Designator | UNC |