| Part No. : JC3-C3-15-2 | Alternate P/N : JC3C3152 | Manufacturer : eaton corporation |
| Item Name: circuit breaker | NSN: 5925-00-336-1992 (5925003361992) | CAGE Code: 74193 |
| FSC: 5925 Circuit Breakers |
If you require part number JC3-C3-15-2 from Eaton Corporation which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number JC3-C3-15-2 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925003361992 and was produced under the CAGE Code 74193. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part JC3-C3-15-2 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| MRC | Criteria | Characteristic |
|---|---|---|
| CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
| AKPX | Pole Quantity | 3 |
| ABXD | Bushing Length | 0.098 INCHES MINIMUM AND 0.162 INCHES MAXIMUM |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| TTQY | Terminal Type And Quantity | 6 QUICK DISCONNECT, MALE |
| THSD | Thread Series Designator | UNC |
| CPRX | Actuator Position Designation | AT EACH POLE |
| CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
| ADAT | Body Width | 2.218 INCHES MINIMUM AND 2.282 INCHES MAXIMUM |
| CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| CPRW | Actuator Function | TRIP-RESET |
| ADTV | Case Material | PLASTIC |
| CQJX | Nominal Thread Size | 0.138 INCHES |
| AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
| AJWX | Mounting Surface To Terminal End Distance | 1.898 INCHES MINIMUM AND 1.962 INCHES MAXIMUM |
| ADAQ | Body Length | 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.528 INCHES MINIMUM AND 1.592 INCHES MAXIMUM |
| AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
| APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
| CMLP | Thread Quantity Per Inch | 32 |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| AFJN | Fragility Factor | MODERATELY RUGGED |
| CPRQ | Reset Method | MANUAL |
| CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| MRC | Decoded Requirement | Clear Text Reply |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.628 INCHES MINIMUM AND 1.692 INCHES MAXIMUM |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.