| Part No. : FN810 | Manufacturer : filtronetics inc | Item Name: filter radio frequency interfere |
| NSN: 5915-01-324-0603 (5915013240603) | CAGE Code: 53733 | FSC: 5915 Filters and Networks |
If you require part number FN810 from Filtronetics Inc which is described as a Filter Radio Frequency Interfere component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number FN810 which is listed under the Federal Supply Class 5915 Filters and Networks. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5915013240603 and was produced under the CAGE Code 53733. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part FN810 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5915-01-324-0603 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 013240603 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| H960047-001B | 6 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 7.740 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 6.800 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 5.500 INCHES NOMINAL |
| ADAT | BODY WIDTH | 6.940 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 4.600 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 6.250 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.8 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.9 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 4.5 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 4.8 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 7.3 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 77.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.03 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.09 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.09 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.15 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.2 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 0.25 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
| AHCG | MAXIMUM TEMP RISE | 30.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 TERMINAL |
| CBBL | FEATURES PROVIDED | MOUNTING BRACKET |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 15.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 15.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 17.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 5.2 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 7.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 7.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| CRST | BODY SURFACE TREATMENT | TIN |
| CTJS | UNPACKAGED UNIT WEIGHT | 14.500 POUNDS NOMINAL |
| FEAT | SPECIAL FEATURES | THIRTY-THREE FILTERED FUNCTIONS |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload