Part No. : 1898 | Manufacturer : frick gallagher mfg co | Item Name: transformer power |
NSN: 5950-01-214-4200 (5950012144200) | CAGE Code: 23591 | FSC: 5950 Coils and Transformers |
If you require part number 1898 from Frick Gallagher Mfg Co which is described as a Transformer Power component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 1898 which is listed under the Federal Supply Class 5950 Coils and Transformers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5950012144200 and was produced under the CAGE Code 23591. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 1898 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 1898
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-214-4200 Item Description: Transformer Power | 5950 | 012144200 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1898 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.800 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.900 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.800 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 18.5 KILOHERTZ MINIMUM AND 25.6 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 4 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.098 AMPERES DC MINIMUM AND 0.102 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.137 AMPERES DC MINIMUM AND 0.143 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 0.147 AMPERES DC MINIMUM AND 0.153 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.196 AMPERES AC MINIMUM AND 0.204 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 0.54 AMPERES DC MINIMUM AND 0.56 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 10.78 AMPERES DC MINIMUM AND 11.22 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 10.44 AC VOLTS MINIMUM AND 10.86 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 20.87 AC VOLTS MINIMUM AND 21.73 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 28.17 AC VOLTS MINIMUM AND 29.31 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 35.47 AC VOLTS MINIMUM AND 36.91 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.02 AC VOLTS MINIMUM AND 6.26 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 6.26 AC VOLTS MINIMUM AND 6.52 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 64.70 AC VOLTS MINIMUM AND 67.60 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 26 PIN |