Part No. : AKR-10S-30 | Alternate P/N : AKR10S30 | Manufacturer : general electric company |
Item Name: circuitbreaker | NSN: 5925-01-397-0559 (5925013970559) | CAGE Code: 60969 |
FSC: 5925 Circuit Breakers |
If you require part number AKR-10S-30 from General Electric Company which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number AKR-10S-30 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925013970559 and was produced under the CAGE Code 60969. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part AKR-10S-30 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. AKR-10S-30
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-397-0559 Item Description: Circuitbreaker | 5925 | 013970559 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Akr-10s-30 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
CQQC | Trip Release Duty Cycle | INTERMITTENT ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
FEAT | Special Features | ITEM IS AN AIR CIRCUIT BREAKER DRAWOUT TYPE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | UNDERVOLTAGE SECOND LOCATION |
CPRK | Auxiliary Trip Coil Voltage Type And Rating In Volts | 120.0 AC NOMINAL ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT FIRST LOCATION |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | ELECTRIC |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPSM | Internal Trip Release Configuration | SERIES TRIP W/AUXILIARY LOAD TERMINAL AND REMOTE TRIP FEATURE ALL LOCATIONS |
AGAV | End Item Identification | SWITCHBOARD ONBOARD 210 FT MMA CLASS COAST GUARD VESSELS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 800.0 AMPERES AC ALL LOCATIONS |
ADTV | Case Material | METAL |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AKPX | Pole Quantity | 3 |