| Part No. : 10000092P01 | Manufacturer : general electric company | Item Name: powersupply |
| NSN: 6130-01-115-3268 (6130011153268) | CAGE Code: 66434 | FSC: 6130 Converters Electrical Non Rotating |
If you require part number 10000092P01 from General Electric Company which is described as a Powersupply component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 10000092P01 which is listed under the Federal Supply Class 6130 Converters Electrical Non Rotating. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6130011153268 and was produced under the CAGE Code 66434. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 10000092P01 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6130-01-115-3268 Item PartTypeName: POWER SUPPLY | 6130 | 011153268 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 10000092P01 | 5 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 1.500 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 4.500 INCHES NOMINAL |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
| ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL 1ST OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 230.0 AC VOLTS NOMINAL 2ND OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 450.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 450.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
| AYNH | OPERATING AMBIENT TEMP RANGE | 40.0 TO 70.0 DEG CELSIUS |
| BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
| BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE SINGLE POWER OUTPUT |
| CBBL | FEATURES PROVIDED | FILTER |
| CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | BLADE SINGLE POWER OUTPUT |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.