Part No. : G330048S7 | Manufacturer : harris corporation | Item Name: switch flow |
NSN: 5930-00-491-5437 (5930004915437) | CAGE Code: 24930 |
If you require part number G330048S7 from Harris Corporation which is described as a Switch Flow component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number G330048S7 which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5930004915437 and was produced under the CAGE Code 24930. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part G330048S7 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-491-5437 Item PartTypeName: SWITCH,FLOW | 5930 | 004915437 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6250F61 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |
ABHP | OVERALL LENGTH | 3.185 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.600 INCHES NOMINAL |
ABPM | BODY DIAMETER | 2.370 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.410 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | -10.0 DEG CELSIUS MINIMUM AND 65.0 DEG CELSIUS MAXIMUM |
AXGY | MOUNTING METHOD | LINE |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | CONNECTOR,RECEPTACLE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 0.55 ACTUATION POINT NOMINAL GALLONS PER MINUTE AND 0.45 DEACTUATION POINT NOMINAL GALLONS PER MINUTE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 50.0 DC AT SEA LEVEL SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
STYL | STYLE DESIGNATOR | CYLINDRICAL |