Part No. : J120-180K0.1PCT | Alternate P/N : J120180K01PCT | Manufacturer : jordan electric co |
Item Name: resistor fixed wire wound | NSN: 5905-00-012-1100 (5905000121100) | CAGE Code: 22045 |
FSC: 5905 Resistors |
If you require part number J120-180K0.1PCT from Jordan Electric Co which is described as a Resistor Fixed Wire Wound component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number J120-180K0.1PCT which is listed under the Federal Supply Class 5905 Resistors. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5905000121100 and was produced under the CAGE Code 22045. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part J120-180K0.1PCT today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. J120-180K0.1PCT
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-012-1100 Item Description: Resistor Fixed Wire Wound | 5905 | 000121100 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
J120-180k0.1pct | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0 TO 10.0 |
AAPP | ELECTRICAL RESISTANCE | 180.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.100 TO 0.100 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 145.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.468 INCHES MINIMUM AND 0.520 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.150 FREE AIR |
CBME | CUBIC MEASURE | 0.029 CUBIC INCHES |
PKWT | III UNPACKAGED UNIT WEIGHT | 2.0 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39005 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39005/4 GOVERNMENT SPECIFICATION |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.