Part No. : NZM6B-63 ZM6-33-200-OBI-CNA | Alternate P/N : NZM6B63ZM633200OBICNA | Manufacturer : klockner moeller ltd |
Item Name: circuit breaker | NSN: 5925-01-314-8122 (5925013148122) | CAGE Code: 6Z127 |
FSC: 5925 Circuit Breakers |
If you require part number NZM6B-63 ZM6-33-200-OBI-CNA from Klockner Moeller Ltd which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number NZM6B-63 ZM6-33-200-OBI-CNA which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925013148122 and was produced under the CAGE Code 6Z127. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part NZM6B-63 ZM6-33-200-OBI-CNA today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. NZM6B-63 ZM6-33-200-OBI-CNA
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-314-8122 Item Description: Circuit Breaker | 5925 | 013148122 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Nzm6b-63 Zm6-33-200-Obi-Cna | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | ||
ABHP | OVERALL LENGTH | 210.0 MILLIMETERS NOMINAL |
ABMK | OVERALL WIDTH | 110.0 MILLIMETERS NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 TERMINAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 33.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 200.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 14000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | UNDERVOLTAGE ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 ROTARY |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
ABKW | OVERALL HEIGHT | 180.0 MILLIMETERS NOMINAL |
AKPX | POLE QUANTITY | 3 |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | +100.0/+200.0 AC ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.