| Part No. : RE65GR200 | Manufacturer : military specifications | Item Name: resistor fixed wire wound induct |
| NSN: 5905-00-827-7992 (5905008277992) | CAGE Code: 81349 | FSC: 5905 Resistors |
If you require part number RE65GR200 from Military Specifications which is described as a Resistor Fixed Wire Wound Induct component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number RE65GR200 which is listed under the Federal Supply Class 5905 Resistors. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5905008277992 and was produced under the CAGE Code 81349. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part RE65GR200 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5905-00-827-7992 Item PartTypeName: RESISTOR,FIXED,WIRE WOUND,INDUCT | 5905 | 008277992 | N | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 859002-0007 | 1 | 1 | C | A |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
| AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
| ADAQ | BODY LENGTH | 0.688 INCHES MINIMUM AND 0.812 INCHES MAXIMUM |
| AEFB | POWER DISSIPATION RATING IN WATTS | 6.000 FREE AIR |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | ENCASED |
| CBME | CUBIC MEASURE | 0.177 CUBIC INCHES |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-18546 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
| AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
| AAPP | ELECTRICAL RESISTANCE | 0.200 OHMS |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 0.312 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.376 INCHES MINIMUM AND 0.500 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 0.375 INCHES MINIMUM AND 0.437 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.552 INCHES MINIMUM AND 0.572 INCHES MAXIMUM |
| AFWW | TERMINAL WIDTH | 0.140 INCHES MINIMUM |
| BYML | MOUNTING HOLE SIZE | 0.089 INCHES MINIMUM AND 0.099 INCHES MAXIMUM |
| CSCF | TERMINAL TYPE | TAB,SOLDER LUG |
| PKWT | UNPACKAGED UNIT WEIGHT | 8.0 GRAMS |
| STYL | STYLE DESIGNATOR | AXIAL TERMINAL S) |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-18546/1 GOVERNMENT SPECIFICATION |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload