Part No. : 583-G111-J3M1-C4S1U-10A | Alternate P/N : 583G111J3M1C4S1U10A | Manufacturer : oakland industries ltd |
Item Name: circuitbreaker | NSN: 5925-01-582-4348 (5925015824348) | CAGE Code: 06402 |
If you require part number 583-G111-J3M1-C4S1U-10A from Oakland Industries Ltd which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 583-G111-J3M1-C4S1U-10A which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925015824348 and was produced under the CAGE Code 06402. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 583-G111-J3M1-C4S1U-10A today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-582-4348 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015824348 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
583-G111-J3M1-C4S1U-10A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
SUPP | Supplementary Features | ITEM HAS AUXILIARY CONTACT (N/C) (CONNECTOR TO EN 3155-016M2018, SIZE 20); BARRIER INCLUDED (19.5 WIDE AND 37.7 LONG-BOTH MM; VOLT DROP PER POLE 190 MV |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 200.0 AC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2500.0 AC ALL LOCATIONS AND 6000.0 DC ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | -55.0 DEG CELSIUS MINIMUM ALL LOCATIONS AND 90.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CMLP | Thread Quantity Per Inch | 32 |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 6 SCREW |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CXCY | Part Name Assigned By Controlling Agency | HIGH PERFORMANCE THERMAL CIRCUIT BREAKER |
AKPX | Pole Quantity | 3 |
CPRJ | Trip Release Method | THERMAL ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
CQJX | Nominal Thread Size | 6.0 MILLIMETERS |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.