| Part No. : 305-00006-02 | Alternate P/N : 3050000602 | Manufacturer : oeco corp |
| Item Name: resistor thermal | NSN: 5905-01-314-5713 (5905013145713) | CAGE Code: 95266 |
| FSC: 5905 Resistors |
If you require part number 305-00006-02 from Oeco Corp which is described as a Resistor Thermal component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 305-00006-02 which is listed under the Federal Supply Class 5905 Resistors. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5905013145713 and was produced under the CAGE Code 95266. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 305-00006-02 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5905-01-314-5713 Item PartTypeName: RESISTOR,THERMAL | 5905 | 013145713 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 305-00006-02 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| AASA | THREAD LENGTH | 0.160 INCHES MINIMUM AND 0.180 INCHES MAXIMUM |
| ABHP | OVERALL LENGTH | 11.260 INCHES MINIMUM AND 13.260 INCHES MAXIMUM |
| ABJT | TERMINAL LENGTH | 11.000 INCHES MINIMUM AND 13.000 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 0.270 INCHES MAXIMUM |
| ADAV | OVERALL DIAMETER | 0.260 INCHES MAXIMUM |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 0.014 WATTS |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 75.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.8 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -3.90 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.9 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 28.5 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 294.0 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 401.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 504.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 549.2 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 74.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 924.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.5 TO 12.5 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.5 TO 12.5 5TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.5 TO 14.5 6TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.3 TO 16.3 7TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.8 TO 17.8 8TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -19.2 TO 19.2 9TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -19.3 TO 19.3 2ND RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.1 TO 20.1 1ST RESISTANCE-TEMPERATURE POINT |
| AGAV | END ITEM IDENTIFICATION | 5805-01-187-9399 SWITCHBOARD,TELEPHONE |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CBME | CUBIC MEASURE | 0.704 CUBIC INCHES |
| CGGK | MOUNTING THREAD QUANTITY | 32 PER INCH |
| CQWD | ZERO POWER RESISTANCE | 10.000 KILOHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| CRYY | MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | 0.138 INCHES |
| STYL | STYLE DESIGNATOR | SCREW MOUNTED |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload