| Part No. : VB04602R | Manufacturer : prestolite electric inc | Item Name: regulator engine generator |
| NSN: 2920-00-884-8151 (2920008848151) | CAGE Code: 68505 | FSC: 2920 Engine Electrical System Components Nonaircraft |
If you require part number VB04602R from Prestolite Electric Inc which is described as a Regulator Engine Generator component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number VB04602R which is listed under the Federal Supply Class 2920 Engine Electrical System Components Nonaircraft. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 2920008848151 and was produced under the CAGE Code 68505. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part VB04602R today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 2920-00-884-8151 Item PartTypeName: REGULATOR,ENGINE GENERATOR | 2920 | 008848151 | N | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| CH871763 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARB | TERMINAL TYPE | SCREW |
| ADER | MOUNTING STYLE | THREE HOLE TRIANGULAR |
| ADNZ | DISTANCE BETWEEN HOLES ALONG WIDTH | 1.310 INCHES NOMINAL |
| ALBH | RADIO INTERFERENCE SHIELDING | NOT PROVIDED |
| ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 7.0 MINIMUM AND 7.3 MAXIMUM |
| ANYC | SYSTEM VOLTAGE RATING | 6.0 |
| ANYD | SYSTEM GROUND POLARITY | NEGATIVE OR POSITIVE |
| ANYE | VOLTAGE REGULATOR UNIT TYPE | WIRE WOUND COIL |
| ANYJ | CURRENT REGULATOR UNIT TYPE | WIRE WOUND COIL |
| ANYK | CURRENT REGULATOR UNIT QUANTITY | 1 |
| ANYP | OUTPUT CURRENT RATING IN AMPS | 33.0 MINIMUM AND 37.0 MAXIMUM |
| ANYR | CIRCUIT CONTROL DEVICE TYPE | CUTOUT RELAY |
| ANYS | CUT-IN VOLTAGE RATING | 6.2 MINIMUM AND 6.7 MAXIMUM |
| ANYZ | CUTOUT CURRENT RATING IN AMPS | 4.0 MINIMUM AND 6.0 MAXIMUM |
| ANZB | REVERSE CURRENT OVERLOAD CIRCUIT BREAKER | NOT INCLUDED |
| ANZC | FIELD RELAY UNIT | NOT INCLUDED |
| APAK | CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG WIDTH AND HOLE ALONG LENGTH | 3.060 INCHES NOMINAL |
| AARA | TERMINAL QUANTITY | 3 |
| ABTB | MOUNTING HOLE DIAMETER | 0.280 INCHES NOMINAL |
| AGBC | SHOCK MOUNT | NOT PROVIDED |
| ANYH | VOLTAGE REGULATOR UNIT QUANTITY | 1 |
| ANZE | TERMINAL ENCASEMENT | NOT ENCASED |