Part No. : M120BA-1A-1-1-0 | Alternate P/N : M120BA1A110 | Manufacturer : quasar power and technologies inc |
Item Name: powersupply | NSN: 6130-01-485-2464 (6130014852464) | CAGE Code: 0B7R6 |
FSC: 6130 Converters Electrical Non Rotating |
If you require part number M120BA-1A-1-1-0 from Quasar Power And Technologies Inc which is described as a Powersupply component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number M120BA-1A-1-1-0 which is listed under the Federal Supply Class 6130 Converters Electrical Non Rotating. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6130014852464 and was produced under the CAGE Code 0B7R6. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part M120BA-1A-1-1-0 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. M120BA-1A-1-1-0
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-485-2464 Item Description: Powersupply | 6130 | 014852464 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M120ba-1a-1-1-0 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | Overall Length | 482.6 MILLIMETERS NOMINAL |
APTQ | Input Frequency Rating | 48.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 64.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
MRC | Decoded Requirement | Clear Text Reply |
APTQ | Input Frequency Rating | 48.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 64.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTS | Output Frequency Rating | 60.0 HERTZ NOMINAL SINGLE POWER OUTPUT |
CWWB | Battery Recovery Time | 300 |
AKWC | Electrical Power Source Relationship | OPERATING |
ABMK | Overall Width | 714.0 MILLIMETERS MAXIMUM |
AKAE | Maximum Operating Altitude Rating | 10000.0 FEET |
ABKW | Overall Height | 132.1 MILLIMETERS MAXIMUM |
CWGN | Output Phase | SINGLE SINGLE POWER OUTPUT |
APPA | Output Voltage Rating | 115.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT |
CWGH | Output Current Rating | 2000.0 AC VOLT-AMPERE NOMINAL SINGLE POWER OUTPUT |
CXMX | Battery Power Supply Emergency Operating Time | 15 |
APNX | Input Voltage Rating | 84.0 AC POUNDS PER HOUR DRY 1ST OPERATING POWER RQMT AND 185.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST OPERATING POWER RQMT |
APNX | Input Voltage Rating | 180.0 AC POUNDS PER HOUR DRY 2ND OPERATING POWER RQMT AND 260.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT |
CWHF | Output Connection Quantity | 1 SINGLE POWER OUTPUT |
CWHY | Battery Feature And Type | RECHARGEABLE LEAD ACID CELL |
CWJF | Battery Location | INTERNAL |
AEXR | Battery Quantity | 1 |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload