| Part No. : B-562A032 | Alternate P/N : B562A032 | Manufacturer : remtec inc |
| Item Name: insulation sleeving electrical s | NSN: 5970-01-352-5636 (5970013525636) | CAGE Code: 59659 |
| FSC: 5970 Electrical Insulators and Insulating Materials |
If you require part number B-562A032 from Remtec Inc which is described as a Insulation Sleeving Electrical S component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number B-562A032 which is listed under the Federal Supply Class 5970 Electrical Insulators and Insulating Materials. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5970013525636 and was produced under the CAGE Code 59659. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part B-562A032 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5970-01-352-5636 Item PartTypeName: INSULATION SLEEVING,ELECTRICAL,S | 5970 | 013525636 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| B-562A032 | 5 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AFZW | SECOND BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZX | THIRD BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| AGAF | FOURTH BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| AGAF | FOURTH BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.420 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| AFZU | MAIN BODY INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
| AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| AGAB | MAIN BODY WALL THICKNESS | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| HUES | COLOR | BLACK |
| ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
| AFZV | FIRST BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| AFZW | SECOND BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZZ | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH | 1.940 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.770 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAB | MAIN BODY WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
| AGAC | FIRST BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAD | SECOND BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| AGAD | SECOND BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAE | THIRD BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| FLEX | FLEXIBILITY | FLEXIBLE |
| MATT | MATERIAL | PLASTIC CROSS-LINKED POLYOLEFIN |
| STYL | STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
| UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 135.0 DEG CELSIUS |
| AFZU | MAIN BODY INSIDE DIAMETER | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZV | FIRST BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZX | THIRD BRANCH INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AGAC | FIRST BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| AGAE | THIRD BRANCH WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| CQBC | MINIMUM TENSILE STRENGTH | 1200 POUNDS PER SQUARE INCH |