Part No. : D1A-100T0550DEGF | Alternate P/N : D1A100T0550DEGF | Manufacturer : robertshaw controls company |
Item Name: switch thermostatic | NSN: 5930-00-969-3282 (5930009693282) | CAGE Code: 33371 |
FSC: 5930 Switches |
If you require part number D1A-100T0550DEGF from Robertshaw Controls Company which is described as a Switch Thermostatic component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number D1A-100T0550DEGF which is listed under the Federal Supply Class 5930 Switches. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5930009693282 and was produced under the CAGE Code 33371. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part D1A-100T0550DEGF today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-969-3282 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 009693282 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
D1A-100T0550DEGF | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.906 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.063 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 36.000 INCHES NOMINAL |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | TUBING END SEAL CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 35.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 100.00 TO 550.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload