Part No. : E2A251 | Manufacturer : rockwell automation ltd | Item Name: resistor variable nonwire wound |
NSN: 5905-01-145-4549 (5905011454549) | CAGE Code: 01121 | FSC: 5905 Resistors |
If you require part number E2A251 from Rockwell Automation Ltd which is described as a Resistor Variable Nonwire Wound component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number E2A251 which is listed under the Federal Supply Class 5905 Resistors. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5905011454549 and was produced under the CAGE Code 01121. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part E2A251 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-145-4549 Item PartTypeName: RESISTOR,VARIABLE,NONWIRE WOUND | 5905 | 011454549 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
72PR250 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.375 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.125 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.375 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.375 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.375 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.375 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 240.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 250.000 OHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CQTM | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |