Part No. : 214-0006-009 | Alternate P/N : 2140006009 | Manufacturer : rockwell collins inc |
Item Name: circuit breaker | NSN: 5925-01-050-9030 (5925010509030) | CAGE Code: 95105 |
FSC: 5925 Circuit Breakers |
If you require part number 214-0006-009 from Rockwell Collins Inc which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 214-0006-009 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925010509030 and was produced under the CAGE Code 95105. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 214-0006-009 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 214-0006-009
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-050-9030 Item Description: Circuit Breaker | 5925 | 010509030 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
214-0006-009 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 3 COMPRESSION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.250 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
MRC | Decoded Requirement | Clear Text Reply |
AXHR | Mounting Facility Type And Quantity | 6 TERMINAL |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.230 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 3 CLIP AND |
ADAQ | Body Length | 6.250 INCHES NOMINAL |
ADAU | Body Height | 2.580 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 240.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE TWO |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.