Part No. : AS58091 | Manufacturer : sae international | Item Name: circuit breaker |
NSN: 5925-01-296-4365 (5925012964365) | CAGE Code: 0U583 | FSC: 5925 Circuit Breakers |
If you require part number AS58091 from Sae International which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number AS58091 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925012964365 and was produced under the CAGE Code 0U583. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part AS58091 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. AS58091
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-296-4365 Item Description: Circuit Breaker | 5925 | 012964365 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
As58091 | 5 | 1 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.780 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.593 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.593 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.525 INCHES NOMINAL |
AKPX | POLE QUANTITY | 4 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC ALL LOCATIONS AND 2000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERVOLTAGE ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3600.000 NOMINAL AT 130 PCT ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 71.0 DEG FAHRENHEIT MAXIMUM ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 380.0 ALL LOCATIONS OR 420.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS26574 GOVERNMENT STANDARD |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload