| Part No. : 67C14-7 12 | Alternate P/N : 67C14712 | Manufacturer : sensata technologies inc |
| Item Name: circuit breaker | NSN: 5925-01-131-1694 (5925011311694) | CAGE Code: 82647 |
| FSC: 5925 Circuit Breakers |
If you require part number 67C14-7 12 from Sensata Technologies Inc which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 67C14-7 12 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925011311694 and was produced under the CAGE Code 82647. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 67C14-7 12 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-131-1694 Item PartTypeName: CIRCUIT BREAKER | 5925 | 011311694 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 6TC14-7.5 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.840 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.750 INCHES NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.704 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.624 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.530 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 7.5 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.550 MINIMUM AT 500 PCT ALL LOCATIONS AND 3.500 MAXIMUM AT 500 PCT ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |