Part No. : IULDHK-111-1-64-6.50-B-91 | Alternate P/N : IULDHK111164650B91 | Manufacturer : sensata technologies inc |
Item Name: circuit breaker | NSN: 5925-01-611-0172 (5925016110172) | CAGE Code: 82647 |
FSC: 5925 Circuit Breakers |
If you require part number IULDHK-111-1-64-6.50-B-91 from Sensata Technologies Inc which is described as a Circuit Breaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number IULDHK-111-1-64-6.50-B-91 which is listed under the Federal Supply Class 5925 Circuit Breakers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925016110172 and was produced under the CAGE Code 82647. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part IULDHK-111-1-64-6.50-B-91 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-611-0172 Item PartTypeName: CIRCUIT BREAKER | 5925 | 016110172 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
IULDHK-111-1-64-6.50-B-91 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 2.50 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.750 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.060 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | GENERALSPT |
AJEC | BOSS HEIGHT | 0.150 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.020 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 65.0 DC AND 480.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MAGNETIC CIRCUIT PROTECTOR |
THSD | THREAD SERIES DESIGNATOR | ISO M |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |