Part No. : APL-1-1-42-103-A | Alternate P/N : APL1142103A | Manufacturer : sensata technologies inc |
Item Name: circuitbreaker | NSN: 5925-01-478-6154 (5925014786154) | CAGE Code: 81541 |
If you require part number APL-1-1-42-103-A from Sensata Technologies Inc which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number APL-1-1-42-103-A which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925014786154 and was produced under the CAGE Code 81541. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part APL-1-1-42-103-A today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-478-6154 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014786154 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
APL-1-1-42-103-A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 1 |
AAQL | Body Style | SINGLE POLE TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC SINGLE LOCATION |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2100.0 AC SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 SINGLE LOCATION |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.490 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 22.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload