| Part No. : R11-2-10.0A-806EV | Alternate P/N : R112100A806EV | Manufacturer : sensata technologies inc |
| Item Name: circuitbreaker | NSN: 5925-01-370-0889 (5925013700889) | CAGE Code: 81541 |
If you require part number R11-2-10.0A-806EV from Sensata Technologies Inc which is described as a Circuitbreaker component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number R11-2-10.0A-806EV which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5925013700889 and was produced under the CAGE Code 81541. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part R11-2-10.0A-806EV today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-370-0889 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013700889 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| R11-2-10.0A-B06EV | 5 | 1 | C | A |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| ABHP | OVERALL LENGTH | 1.840 INCHES NOMINAL |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC AND 10.0 AMPERES DC SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG |
| AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
| ABKW | OVERALL HEIGHT | 0.400 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 1.560 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC AND 2000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CWJK | CASE MATERIAL | PLASTIC |
| AKPX | POLE QUANTITY | 1 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC AND 32.0 DC SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.750 MINIMUM AT 200 PCT AND 30.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 SINGLE LOCATION |