Part No. : 7J0ZT | Manufacturer : sigma instruments inc | Item Name: relay electromagnetic |
NSN: 5945-00-239-2413 (5945002392413) | CAGE Code: 78277 | FSC: 5945 Relays and Solenoids |
If you require part number 7J0ZT from Sigma Instruments Inc which is described as a Relay Electromagnetic component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 7J0ZT which is listed under the Federal Supply Class 5945 Relays and Solenoids. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5945002392413 and was produced under the CAGE Code 78277. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 7J0ZT today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 7J0ZT
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.590 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.120 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.590 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 3 |
APCN | COIL QUANTITY | 2 |
APNA | WINDING DC RESISTANCE RATING | 150.0 OHMS NOMINAL FIRST WINDING |
APNA | WINDING DC RESISTANCE RATING | 150.0 OHMS NOMINAL SECOND WINDING |
APNA | WINDING DC RESISTANCE RATING | 20.0 OHMS NOMINAL THIRD WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | INERT GAS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS |
CTCN | MINIMUM DIFFERENTIAL ELECTRICAL OPERATING RATING | 2.1 MILLIAMPERES |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 MILLIAMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 DC |
FEAT | SPECIAL FEATURES | OPERATING CURRENT TYPE DC; INCLUDES DAMPING COIL TO PREVENT CONTACT BOUNCE |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload