Part No. : C4300-086X | Alternate P/N : C4300086X | Manufacturer : taylor and gaskin inc |
Item Name: switch thermostatic | NSN: 5930-00-249-4605 (5930002494605) | CAGE Code: 45510 |
FSC: 5930 Switches |
If you require part number C4300-086X from Taylor And Gaskin Inc which is described as a Switch Thermostatic component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number C4300-086X which is listed under the Federal Supply Class 5930 Switches. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5930002494605 and was produced under the CAGE Code 45510. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part C4300-086X today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-249-4605 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 002494605 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
L28-5073P1 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 4.344 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 3.719 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AWTN | OPERATING TEMP RATING | -100.0 DEG FAHRENHEIT MINIMUM AND 147.5 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | CLAMP |
CBBL | FEATURES PROVIDED | AUTOMATIC RESET |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE,PRESET AND ACTUATION POINT ADJUSTABLE,PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | -100.00 TO 400.00 ACTUATION POINT DEGREES FAHRENHEIT AND-100.00 TO 400.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
CTYX | CONTACT STIMULUS RATING | 85.00 ACTUATION POINT NOMINAL DEGREES CELSIUS AND 84.00 DEACTUATION POINT NOMINAL DEGREES CELSIUS AND 1.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | CYLINDRICAL |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.