Part No. : JFS0500-24 | Alternate P/N : JFS050024 | Manufacturer : tdk lambda ltd |
Item Name: power supply | NSN: 6130-01-476-2226 (6130014762226) | CAGE Code: 9T790 |
If you require part number JFS0500-24 from Tdk Lambda Ltd which is described as a Power Supply component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number JFS0500-24 which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6130014762226 and was produced under the CAGE Code 9T790. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part JFS0500-24 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-476-2226 Item PartTypeName: POWER SUPPLY | 6130 | 014762226 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
JFS0500-24 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 12.130 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.870 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AMQY | INSTALLATION DESIGN | BRACKET |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 265.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 85.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ NOMINAL 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 63.0 HERTZ NOMINAL 2ND OPERATING POWER RQMT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT AND RANGE SINGLE POWER OUTPUT |
BGQR | OUTPUT WATTAGE RATING | 500.0 WATTS NOMINAL SINGLE POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 10.4 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 20.8 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | OPERATING TEMP RANGE: -20 C TO 70 C WITH LINEAR DERATING ABOUT 50 C(50% @ 70 C)(-20C REQUIRES A 30 MIN. WARM-UP PERIOD); STORAGE TEMP: -40 C TO +85 C; COOLING BY INTERNAL FAN |