Part No. : AB4111 1 | Alternate P/N : AB41111 | Manufacturer : tyco electronics corp |
Item Name: relay electromagnetic | NSN: 5945-00-902-5907 (5945009025907) | CAGE Code: 77342 |
FSC: 5945 Relays and Solenoids |
If you require part number AB4111 1 from Tyco Electronics Corp which is described as a Relay Electromagnetic component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number AB4111 1 which is listed under the Federal Supply Class 5945 Relays and Solenoids. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5945009025907 and was produced under the CAGE Code 77342. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part AB4111 1 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. AB4111 1
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SECOND MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.620 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.650 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.170 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AGAV | END ITEM IDENTIFICATION | TYPE NO. FA-6253 |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 3.2 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL FIRST MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SECOND MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | POLARIZED |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.875 INCHES NOMINAL SECOND MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 240.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 STANDARD TUBE BASE ENERGIZING ELEMENT |
TTQY | TERMINAL TYPE AND QUANTITY | 6 STANDARD TUBE BASE CONTACTS |