Part No. : 16-9-449014 | Alternate P/N : 169449014 | Manufacturer : varityper inc |
Item Name: transformer power | NSN: 5950-01-323-1671 (5950013231671) | CAGE Code: 62812 |
FSC: 5950 Coils and Transformers |
If you require part number 16-9-449014 from Varityper Inc which is described as a Transformer Power component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 16-9-449014 which is listed under the Federal Supply Class 5950 Coils and Transformers. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5950013231671 and was produced under the CAGE Code 62812. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 16-9-449014 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 16-9-449014
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-323-1671 Item Description: Transformer Power | 5950 | 013231671 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
16-9-449014 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT AND INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AGAV | END ITEM IDENTIFICATION | 3610-01-256-0545,PHOTOTYPESETTER |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.4 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS MINIMUM SINGLE COMPONENT ALL PRIMARY AND 130.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 171.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 38.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS; 6 SECONDARY WINDINGS; ALL SECONDARY CURRENTS ARE RECTIFIED DC |
TTQY | TERMINAL TYPE AND QUANTITY | 19 TAB, SOLDER LUG |
ABKW | OVERALL HEIGHT | 6.500 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.7 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 18.90 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES DC MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 50.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload