Part No. : 100-1-5K | Alternate P/N : 10015K | Manufacturer : vernitron corp |
Item Name: resistor variable wire wound non | NSN: 5905-01-016-2364 (5905010162364) | CAGE Code: 84048 |
FSC: 5905 Resistors |
If you require part number 100-1-5K from Vernitron Corp which is described as a Resistor Variable Wire Wound Non component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 100-1-5K which is listed under the Federal Supply Class 5905 Resistors. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 5905010162364 and was produced under the CAGE Code 84048. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 100-1-5K today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-016-2364 Item PartTypeName: RESISTOR,VARIABLE,WIRE WOUND,NON | 5905 | 010162364 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
100-1-5K | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.422 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.187 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.235 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.500 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 315.0 NOMINAL |
AEFL | MAXIMUM RUNNING TORQUE | 0.25 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0 TO 50.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload