Part No. : 24103 | Manufacturer : ward leonard electric company inc | Item Name: starter motor |
NSN: 6110-01-145-2746 (6110011452746) | CAGE Code: 63743 |
If you require part number 24103 from Ward Leonard Electric Company Inc which is described as a Starter Motor component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 24103 which is listed under the Federal Supply Class . To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6110011452746 and was produced under the CAGE Code 63743. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 24103 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 24103
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6110-01-145-2746 Item Description: Starter Motor | 6110 | 011452746 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
24103 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABBB | SPEED ADJUSTMENTS | 0 TO FULL SPEED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
ABHP | OVERALL LENGTH | 17.125 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 9.093 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 8.875 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AFLW | ACTUATION METHOD | MAGNETIC |
AGLD | PERFORMANCE TYPE | AUTOMATIC |
AJXE | SIZE DESIGNATOR | 0 |
AKPS | DUTY CYCLE | CONTINUOUS |
ALGC | MOUNTING CONFIGURATION | FOUR 15/32 IN. DIA HOLES ON 6-3/4 IN. BY 12-1/2 IN. RECTANGULAR CENTERS |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
ANDE | ACTUATOR VOLTAGE | 115.0 AC |
ANDW | LOAD PROTECTION TYPE | OVERLOAD OR UNDERVOLTAGE |
ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
ANPZ | INCLOSURE FEATURE | DRIPPROOF |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
ANRK | SWITCH FUNCTIONAL POSITIONS | EMERGENCY RUN AND OVERLOAD RESET |
AQZF | CONTROL TYPE | LOCAL OR REMOTE |
FAAZ | PHASE | THREE |
FREQ | FREQUENCY IN HERTZ | 60.0 |