Part No. : 23993 | Manufacturer : ward leonard electric company inc | Item Name: starter motor |
NSN: 6110-01-123-1872 (6110011231872) | CAGE Code: 63743 | FSC: 6110 Electrical Control Equipment |
If you require part number 23993 from Ward Leonard Electric Company Inc which is described as a Starter Motor component ASAP Logistic Solutions is your sourcing solution. On this page, you can request a quote on part number 23993 which is listed under the Federal Supply Class 6110 Electrical Control Equipment. To ensure that you only procure the exact item you need to be sure to note that this particular product is listed with the NSN 6110011231872 and was produced under the CAGE Code 63743. To learn more about this listing or to simply initiate the purchasing process, complete and submit the RFQ form on this page for part 23993 today Within 15 minutes of receiving and reviewing a completed request based on the information you provide a member of our staff will contact you to provide a tailored solution to your comparison needs. 23993
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6110-01-123-1872 Item Description: Starter Motor | 6110 | 011231872 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
23993 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABBB | SPEED ADJUSTMENTS | 0 TO FULL SPEED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF AND SHOCK PROOF |
ABHP | OVERALL LENGTH | 8.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 14.375 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 12.000 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AFLW | ACTUATION METHOD | MAGNETIC |
AGLD | PERFORMANCE TYPE | AUTOMATIC |
AGUE | FUSE ACCOMMODATION QUANTITY | 3 |
AJXE | SIZE DESIGNATOR | 0 |
AKPS | DUTY CYCLE | CONTINUOUS |
ALGC | MOUNTING CONFIGURATION | FOUR 15/32 IN. DIA MTG HOLES FOR 7/16 IN. DIA MTG BOLTS ON 12-3/8 IN. BY 10 IN. MTG CTR |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
ANDE | ACTUATOR VOLTAGE | 440.0 AC |
ANDG | FUSE CURRENT RATING IN AMPS | 10.0 |
ANDW | LOAD PROTECTION TYPE | OVERLOAD |
ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
ANPZ | INCLOSURE FEATURE | FULLY INCLOSED |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
ANRK | SWITCH FUNCTIONAL POSITIONS | CLOSE AND EMERGENCY RUN AND OPEN AND STOP AND EMERGENCY CLOSE |
AQZF | CONTROL TYPE | LOCAL |
CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
FAAZ | PHASE | THREE |
FREQ | FREQUENCY IN HERTZ | 60.0 |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload